Commit tune maps and research so tunes are reachable from the phone
Removes the *.hex/maps_cache gitignore rule (explicit user call, reversing the earlier no-redistribution stance) so the official TuneECU catalogue maps, derived SAI/O2-delete composites, and the checksum/composition tooling are actually available to pull up on a phone browser when using the real TuneECU app. Also folds in tonight's KWP2000 fixes (TesterPresent keep-alive, connect-failure cleanup, slow-init StartCommunication fix) and the accumulated research docs. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01FP2GaxS9HkUdL5sLBnjKje
This commit is contained in:
7
tunie/logs/tunie-bt-reset-20260826-201049.txt
Normal file
7
tunie/logs/tunie-bt-reset-20260826-201049.txt
Normal file
@@ -0,0 +1,7 @@
|
||||
$ /opt/homebrew/bin/blueutil --disconnect 04-25-E8-5B-03-75
|
||||
$ /opt/homebrew/bin/blueutil --connect 04-25-E8-5B-03-75
|
||||
$ /opt/homebrew/bin/blueutil --info 04-25-E8-5B-03-75
|
||||
address: 04-25-e8-5b-03-75, not connected, not favourite, not paired, name: "04:25:E8:5B:03:75", recent access date: 2026-08-27 01:10:58 +0000
|
||||
|
||||
NOT connected after reset
|
||||
(full session log: logs/tunie-bt-reset-20260826-201049.txt)
|
||||
7
tunie/logs/tunie-bt-reset-20260826-201213.txt
Normal file
7
tunie/logs/tunie-bt-reset-20260826-201213.txt
Normal file
@@ -0,0 +1,7 @@
|
||||
$ /opt/homebrew/bin/blueutil --disconnect 04-25-E8-5B-03-75
|
||||
$ /opt/homebrew/bin/blueutil --connect 04-25-E8-5B-03-75
|
||||
$ /opt/homebrew/bin/blueutil --info 04-25-E8-5B-03-75
|
||||
address: 04-25-e8-5b-03-75, not connected, not favourite, not paired, name: "04:25:E8:5B:03:75", recent access date: 2026-08-27 01:12:25 +0000
|
||||
|
||||
NOT connected after reset
|
||||
(full session log: logs/tunie-bt-reset-20260826-201213.txt)
|
||||
7
tunie/logs/tunie-bt-reset-20260826-201312.txt
Normal file
7
tunie/logs/tunie-bt-reset-20260826-201312.txt
Normal file
@@ -0,0 +1,7 @@
|
||||
$ /opt/homebrew/bin/blueutil --disconnect 04-25-E8-5B-03-75
|
||||
$ /opt/homebrew/bin/blueutil --connect 04-25-E8-5B-03-75
|
||||
$ /opt/homebrew/bin/blueutil --info 04-25-E8-5B-03-75
|
||||
address: 04-25-e8-5b-03-75, not connected, not favourite, not paired, name: "04:25:E8:5B:03:75", recent access date: 2026-08-27 01:13:21 +0000
|
||||
|
||||
NOT connected after reset
|
||||
(full session log: logs/tunie-bt-reset-20260826-201312.txt)
|
||||
15
tunie/logs/tunie-info-20260822-142022.txt
Normal file
15
tunie/logs/tunie-info-20260822-142022.txt
Normal file
@@ -0,0 +1,15 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, fast init...
|
||||
Attempt 1/3 failed (timed out waiting for 1 bytes, got 0 (none)); retrying in 5s...
|
||||
Attempt 2/3 failed (timed out waiting for 1 bytes, got 0 (none)); retrying in 5s...
|
||||
|
||||
Connection failed after 3 attempt(s): timed out waiting for 1 bytes, got 0 (none)
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260822-142022.txt)
|
||||
15
tunie/logs/tunie-info-20260822-142121.txt
Normal file
15
tunie/logs/tunie-info-20260822-142121.txt
Normal file
@@ -0,0 +1,15 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, slow init...
|
||||
Attempt 1/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
Attempt 2/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
|
||||
Connection failed after 3 attempt(s): 5-baud init: expected sync byte 0x55, got 00
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260822-142121.txt)
|
||||
15
tunie/logs/tunie-info-20260822-142255.txt
Normal file
15
tunie/logs/tunie-info-20260822-142255.txt
Normal file
@@ -0,0 +1,15 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, slow init...
|
||||
Attempt 1/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
Attempt 2/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
|
||||
Connection failed after 3 attempt(s): 5-baud init: expected sync byte 0x55, got 00
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260822-142255.txt)
|
||||
15
tunie/logs/tunie-info-20260822-142356.txt
Normal file
15
tunie/logs/tunie-info-20260822-142356.txt
Normal file
@@ -0,0 +1,15 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, slow init...
|
||||
Attempt 1/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
Attempt 2/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
|
||||
Connection failed after 3 attempt(s): 5-baud init: expected sync byte 0x55, got 00
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260822-142356.txt)
|
||||
15
tunie/logs/tunie-info-20260822-142418.txt
Normal file
15
tunie/logs/tunie-info-20260822-142418.txt
Normal file
@@ -0,0 +1,15 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, fast init...
|
||||
Attempt 1/3 failed (timed out waiting for 1 bytes, got 0 (none)); retrying in 5s...
|
||||
Attempt 2/3 failed (timed out waiting for 1 bytes, got 0 (none)); retrying in 5s...
|
||||
|
||||
Connection failed after 3 attempt(s): timed out waiting for 1 bytes, got 0 (none)
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260822-142418.txt)
|
||||
11
tunie/logs/tunie-info-20260826-175905.txt
Normal file
11
tunie/logs/tunie-info-20260826-175905.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via kline, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed: timed out waiting for 5 bytes, got 0 (none)
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-175905.txt)
|
||||
11
tunie/logs/tunie-info-20260826-175915.txt
Normal file
11
tunie/logs/tunie-info-20260826-175915.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via kline, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed: timed out waiting for 1 bytes, got 0 (none)
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-175915.txt)
|
||||
11
tunie/logs/tunie-info-20260826-182538.txt
Normal file
11
tunie/logs/tunie-info-20260826-182538.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed: adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-182538.txt)
|
||||
11
tunie/logs/tunie-info-20260826-182555.txt
Normal file
11
tunie/logs/tunie-info-20260826-182555.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed: adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-182555.txt)
|
||||
11
tunie/logs/tunie-info-20260826-182636.txt
Normal file
11
tunie/logs/tunie-info-20260826-182636.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed: adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-182636.txt)
|
||||
11
tunie/logs/tunie-info-20260826-182702.txt
Normal file
11
tunie/logs/tunie-info-20260826-182702.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed: adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-182702.txt)
|
||||
11
tunie/logs/tunie-info-20260826-182721.txt
Normal file
11
tunie/logs/tunie-info-20260826-182721.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed: adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-182721.txt)
|
||||
17
tunie/logs/tunie-info-20260826-193147.txt
Normal file
17
tunie/logs/tunie-info-20260826-193147.txt
Normal file
@@ -0,0 +1,17 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
Attempt 1/5 failed (adapter did not return a prompt for 'ATZ'; partial: ''); retrying in 5s...
|
||||
Attempt 2/5 failed (adapter did not return a prompt for 'ATZ'; partial: ''); retrying in 5s...
|
||||
Attempt 3/5 failed (adapter did not return a prompt for 'ATZ'; partial: ''); retrying in 5s...
|
||||
Attempt 4/5 failed (adapter did not return a prompt for 'ATZ'; partial: ''); retrying in 5s...
|
||||
|
||||
Connection failed after 5 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-193147.txt)
|
||||
2
tunie/logs/tunie-info-20260826-193324.txt
Normal file
2
tunie/logs/tunie-info-20260826-193324.txt
Normal file
@@ -0,0 +1,2 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
Attempt 1/5 failed (adapter did not return a prompt for 'ATZ'; partial: ''); retrying in 5s...
|
||||
11
tunie/logs/tunie-info-20260826-193336.txt
Normal file
11
tunie/logs/tunie-info-20260826-193336.txt
Normal file
@@ -0,0 +1,11 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed: adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-193336.txt)
|
||||
2
tunie/logs/tunie-info-20260826-194806.txt
Normal file
2
tunie/logs/tunie-info-20260826-194806.txt
Normal file
@@ -0,0 +1,2 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
Attempt 1/5 failed (adapter did not return a prompt for 'ATZ'; partial: ''); retrying in 5s...
|
||||
13
tunie/logs/tunie-info-20260826-195018.txt
Normal file
13
tunie/logs/tunie-info-20260826-195018.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed after 1 attempt(s): no hex payload in adapter response: 'BUS INIT: ERROR'
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-195018.txt)
|
||||
13
tunie/logs/tunie-info-20260826-195049.txt
Normal file
13
tunie/logs/tunie-info-20260826-195049.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-195049.txt)
|
||||
13
tunie/logs/tunie-info-20260826-195142.txt
Normal file
13
tunie/logs/tunie-info-20260826-195142.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-195142.txt)
|
||||
1
tunie/logs/tunie-info-20260826-195225.txt
Normal file
1
tunie/logs/tunie-info-20260826-195225.txt
Normal file
@@ -0,0 +1 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
13
tunie/logs/tunie-info-20260826-195246.txt
Normal file
13
tunie/logs/tunie-info-20260826-195246.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-195246.txt)
|
||||
13
tunie/logs/tunie-info-20260826-195326.txt
Normal file
13
tunie/logs/tunie-info-20260826-195326.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-195326.txt)
|
||||
13
tunie/logs/tunie-info-20260826-195512.txt
Normal file
13
tunie/logs/tunie-info-20260826-195512.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter reported 'BUS INIT: ...OK\rNO DATA' for 81
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-195512.txt)
|
||||
13
tunie/logs/tunie-info-20260826-195601.txt
Normal file
13
tunie/logs/tunie-info-20260826-195601.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-195601.txt)
|
||||
38
tunie/logs/tunie-info-20260826-200513.txt
Normal file
38
tunie/logs/tunie-info-20260826-200513.txt
Normal file
@@ -0,0 +1,38 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
|
||||
Diagnostic trouble codes: none reported
|
||||
|
||||
Queries that did not answer
|
||||
ReadEcuIdentification 0x80: adapter did not return a prompt for '1A80'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x81: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x86: adapter did not return a prompt for '1A86'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x87: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x88: adapter did not return a prompt for '1A88'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x89: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x8A: adapter did not return a prompt for '1A8A'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x90: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x91: adapter did not return a prompt for '1A91'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x92: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x93: adapter did not return a prompt for '1A93'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x94: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x95: adapter did not return a prompt for '1A95'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x96: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x97: adapter did not return a prompt for '1A97'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x98: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x99: adapter did not return a prompt for '1A99'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x9A: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x9B: adapter did not return a prompt for '1A9B'; partial: 'BUS INIT: ...'
|
||||
ReadEcuIdentification 0x9C: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x80: adapter did not return a prompt for '2180'; partial: 'BUS INIT: ...'
|
||||
ReadDataByLocalIdentifier 0x81: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x00: adapter did not return a prompt for '2100'; partial: 'BUS INIT: ...'
|
||||
ReadDataByLocalIdentifier 0x01: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x02: adapter did not return a prompt for '2102'; partial: 'BUS INIT: ...'
|
||||
ReadDataByLocalIdentifier 0x03: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x10: adapter did not return a prompt for '2110'; partial: 'BUS INIT: ...'
|
||||
ReadDataByLocalIdentifier 0x11: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDtcByStatus 0x18: adapter did not return a prompt for '1800FF00'; partial: 'BUS INIT: ...'
|
||||
ReadDtc 0x13: adapter did not return a prompt for '1340FF'; partial: 'BUS INIT: ...'
|
||||
|
||||
(full session log: logs/tunie-info-20260826-200513.txt)
|
||||
13
tunie/logs/tunie-info-20260826-200812.txt
Normal file
13
tunie/logs/tunie-info-20260826-200812.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-200812.txt)
|
||||
13
tunie/logs/tunie-info-20260826-200906.txt
Normal file
13
tunie/logs/tunie-info-20260826-200906.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-200906.txt)
|
||||
13
tunie/logs/tunie-info-20260826-201108.txt
Normal file
13
tunie/logs/tunie-info-20260826-201108.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): could not open /dev/cu.vLinkerMC: [Errno 2] could not open port /dev/cu.vLinkerMC: [Errno 2] No such file or directory: '/dev/cu.vLinkerMC'
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-201108.txt)
|
||||
38
tunie/logs/tunie-info-20260826-201432.txt
Normal file
38
tunie/logs/tunie-info-20260826-201432.txt
Normal file
@@ -0,0 +1,38 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
|
||||
Diagnostic trouble codes: none reported
|
||||
|
||||
Queries that did not answer
|
||||
ReadEcuIdentification 0x80: no hex payload in adapter response: '.STOPPED'
|
||||
ReadEcuIdentification 0x81: no hex payload in adapter response: '.STOPPED'
|
||||
ReadEcuIdentification 0x86: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x87: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x88: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x89: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x8A: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x90: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x91: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x92: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x93: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x94: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x95: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x96: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x97: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x98: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x99: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x9A: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x9B: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x9C: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x80: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x81: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x00: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x01: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x02: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x03: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x10: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x11: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDtcByStatus 0x18: adapter did not return a prompt for '1800FF00'; partial: 'BUS INIT: ...'
|
||||
ReadDtc 0x13: adapter did not return a prompt for '1340FF'; partial: 'BUS INIT: ...'
|
||||
|
||||
(full session log: logs/tunie-info-20260826-201432.txt)
|
||||
13
tunie/logs/tunie-info-20260826-201831.txt
Normal file
13
tunie/logs/tunie-info-20260826-201831.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-201831.txt)
|
||||
13
tunie/logs/tunie-info-20260826-201947.txt
Normal file
13
tunie/logs/tunie-info-20260826-201947.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): could not open /dev/cu.vLinkerMC: [Errno 2] could not open port /dev/cu.vLinkerMC: [Errno 2] No such file or directory: '/dev/cu.vLinkerMC'
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-201947.txt)
|
||||
38
tunie/logs/tunie-info-20260826-202004.txt
Normal file
38
tunie/logs/tunie-info-20260826-202004.txt
Normal file
@@ -0,0 +1,38 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
|
||||
Diagnostic trouble codes: none reported
|
||||
|
||||
Queries that did not answer
|
||||
ReadEcuIdentification 0x80: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x81: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x86: no hex payload in adapter response: '.STOPPED'
|
||||
ReadEcuIdentification 0x87: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x88: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x89: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x8A: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x90: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x91: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x92: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x93: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x94: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x95: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x96: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x97: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x98: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x99: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x9A: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x9B: no hex payload in adapter response: 'STOPPED'
|
||||
ReadEcuIdentification 0x9C: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x80: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x81: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x00: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x01: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x02: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x03: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x10: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDataByLocalIdentifier 0x11: no hex payload in adapter response: 'STOPPED'
|
||||
ReadDtcByStatus 0x18: adapter did not return a prompt for '1800FF00'; partial: 'BUS INIT: ...'
|
||||
ReadDtc 0x13: adapter did not return a prompt for '1340FF'; partial: 'BUS INIT: ...'
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202004.txt)
|
||||
13
tunie/logs/tunie-info-20260826-202342.txt
Normal file
13
tunie/logs/tunie-info-20260826-202342.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202342.txt)
|
||||
1
tunie/logs/tunie-info-20260826-202430.txt
Normal file
1
tunie/logs/tunie-info-20260826-202430.txt
Normal file
@@ -0,0 +1 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
13
tunie/logs/tunie-info-20260826-202609.txt
Normal file
13
tunie/logs/tunie-info-20260826-202609.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202609.txt)
|
||||
13
tunie/logs/tunie-info-20260826-202735.txt
Normal file
13
tunie/logs/tunie-info-20260826-202735.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202735.txt)
|
||||
13
tunie/logs/tunie-info-20260826-202801.txt
Normal file
13
tunie/logs/tunie-info-20260826-202801.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202801.txt)
|
||||
13
tunie/logs/tunie-info-20260826-202922.txt
Normal file
13
tunie/logs/tunie-info-20260826-202922.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed after 1 attempt(s): could not open /dev/cu.vLinkerMC: [Errno 2] could not open port /dev/cu.vLinkerMC: [Errno 2] No such file or directory: '/dev/cu.vLinkerMC'
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202922.txt)
|
||||
13
tunie/logs/tunie-info-20260826-202926.txt
Normal file
13
tunie/logs/tunie-info-20260826-202926.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed after 1 attempt(s): could not open /dev/cu.vLinkerMC: [Errno 2] could not open port /dev/cu.vLinkerMC: [Errno 2] No such file or directory: '/dev/cu.vLinkerMC'
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202926.txt)
|
||||
13
tunie/logs/tunie-info-20260826-202947.txt
Normal file
13
tunie/logs/tunie-info-20260826-202947.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, fast init...
|
||||
|
||||
Connection failed after 1 attempt(s): no hex payload in adapter response: 'BUS INIT: ERROR'
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-202947.txt)
|
||||
13
tunie/logs/tunie-info-20260826-203035.txt
Normal file
13
tunie/logs/tunie-info-20260826-203035.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.vLinkerMC via elm327, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): adapter did not return a prompt for 'ATZ'; partial: ''
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-203035.txt)
|
||||
13
tunie/logs/tunie-info-20260826-214932.txt
Normal file
13
tunie/logs/tunie-info-20260826-214932.txt
Normal file
@@ -0,0 +1,13 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, slow init...
|
||||
|
||||
Connection failed after 1 attempt(s): 5-baud init: expected sync byte 0x55, got 00
|
||||
|
||||
Things to check, in order:
|
||||
1. Ignition on, engine off. The ECU sleeps otherwise.
|
||||
2. Diagnostic connector pinout -- confirm before suspecting anything else.
|
||||
3. Try --init slow (5-baud) if fast init times out.
|
||||
4. If retries didn't help, the ignition may need a real power cycle --
|
||||
turn it off, wait a few seconds, back on, and re-run.
|
||||
5. On an ELM327 clone, KWP support is often broken; try the KKL cable.
|
||||
|
||||
(full session log: logs/tunie-info-20260826-214932.txt)
|
||||
3
tunie/logs/tunie-info-20260826-214948.txt
Normal file
3
tunie/logs/tunie-info-20260826-214948.txt
Normal file
@@ -0,0 +1,3 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, fast init...
|
||||
Attempt 1/3 failed (timed out waiting for 1 bytes, got 0 (none)); retrying in 5s...
|
||||
Attempt 2/3 failed (timed out waiting for 1 bytes, got 0 (none)); retrying in 5s...
|
||||
2
tunie/logs/tunie-info-20260826-215009.txt
Normal file
2
tunie/logs/tunie-info-20260826-215009.txt
Normal file
@@ -0,0 +1,2 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, slow init...
|
||||
Attempt 1/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
3
tunie/logs/tunie-info-20260826-215023.txt
Normal file
3
tunie/logs/tunie-info-20260826-215023.txt
Normal file
@@ -0,0 +1,3 @@
|
||||
Connecting on /dev/cu.usbserial-A50285BI via kline, target 0xD5 source 0xF5, slow init...
|
||||
Attempt 1/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
Attempt 2/3 failed (5-baud init: expected sync byte 0x55, got 00); retrying in 5s...
|
||||
2
tunie/logs/tunie-raw-20260826-183647.txt
Normal file
2
tunie/logs/tunie-raw-20260826-183647.txt
Normal file
@@ -0,0 +1,2 @@
|
||||
Opening /dev/cu.doesnotexist @ 38400 baud (settle 2.0s)...
|
||||
could not open /dev/cu.doesnotexist: [Errno 2] could not open port /dev/cu.doesnotexist: [Errno 2] No such file or directory: '/dev/cu.doesnotexist'
|
||||
7
tunie/logs/tunie-raw-20260826-192719.txt
Normal file
7
tunie/logs/tunie-raw-20260826-192719.txt
Normal file
@@ -0,0 +1,7 @@
|
||||
Opening /dev/cu.vLinkerMC @ 38400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- nothing received in 5.0s
|
||||
|
||||
This means the adapter itself never answered -- the problem is upstream of tunie (the OS<->adapter serial/Bluetooth channel), not in tunie's protocol handling. Re-pairing the adapter (forget it in Bluetooth settings, pair fresh) is the next thing to try, not a tunie flag.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-192719.txt)
|
||||
7
tunie/logs/tunie-raw-20260826-192743.txt
Normal file
7
tunie/logs/tunie-raw-20260826-192743.txt
Normal file
@@ -0,0 +1,7 @@
|
||||
Opening /dev/cu.vLinkerMC @ 38400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- nothing received in 5.0s
|
||||
|
||||
This means the adapter itself never answered -- the problem is upstream of tunie (the OS<->adapter serial/Bluetooth channel), not in tunie's protocol handling. Re-pairing the adapter (forget it in Bluetooth settings, pair fresh) is the next thing to try, not a tunie flag.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-192743.txt)
|
||||
7
tunie/logs/tunie-raw-20260826-192837.txt
Normal file
7
tunie/logs/tunie-raw-20260826-192837.txt
Normal file
@@ -0,0 +1,7 @@
|
||||
Opening /dev/cu.vLinkerMC @ 38400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- nothing received in 5.0s
|
||||
|
||||
This means the adapter itself never answered -- the problem is upstream of tunie (the OS<->adapter serial/Bluetooth channel), not in tunie's protocol handling. Re-pairing the adapter (forget it in Bluetooth settings, pair fresh) is the next thing to try, not a tunie flag.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-192837.txt)
|
||||
9
tunie/logs/tunie-raw-20260826-193133.txt
Normal file
9
tunie/logs/tunie-raw-20260826-193133.txt
Normal file
@@ -0,0 +1,9 @@
|
||||
Opening /dev/cu.vLinkerMC @ 38400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- 20 bytes:
|
||||
hex : 41 54 5a 0d 0d 0d 45 4c 4d 33 32 37 20 76 32 2e 32 0d 0d 3e
|
||||
ascii : 'ATZ\r\r\rELM327 v2.2\r\r>'
|
||||
|
||||
Something answered -- the link is alive. If this was an ELM327 adapter and the response doesn't look like an ELM327 banner/prompt, the issue is likely in how tunie is talking to it, not the link itself.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-193133.txt)
|
||||
7
tunie/logs/tunie-raw-20260826-202441.txt
Normal file
7
tunie/logs/tunie-raw-20260826-202441.txt
Normal file
@@ -0,0 +1,7 @@
|
||||
Opening /dev/cu.vLinkerMC @ 38400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- nothing received in 5.0s
|
||||
|
||||
This means the adapter itself never answered -- the problem is upstream of tunie (the OS<->adapter serial/Bluetooth channel), not in tunie's protocol handling. Re-pairing the adapter (forget it in Bluetooth settings, pair fresh) is the next thing to try, not a tunie flag.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-202441.txt)
|
||||
9
tunie/logs/tunie-raw-20260826-202721.txt
Normal file
9
tunie/logs/tunie-raw-20260826-202721.txt
Normal file
@@ -0,0 +1,9 @@
|
||||
Opening /dev/cu.vLinkerMC @ 38400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- 20 bytes:
|
||||
hex : 41 54 5a 0d 0d 0d 45 4c 4d 33 32 37 20 76 32 2e 32 0d 0d 3e
|
||||
ascii : 'ATZ\r\r\rELM327 v2.2\r\r>'
|
||||
|
||||
Something answered -- the link is alive. If this was an ELM327 adapter and the response doesn't look like an ELM327 banner/prompt, the issue is likely in how tunie is talking to it, not the link itself.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-202721.txt)
|
||||
9
tunie/logs/tunie-raw-20260826-214846.txt
Normal file
9
tunie/logs/tunie-raw-20260826-214846.txt
Normal file
@@ -0,0 +1,9 @@
|
||||
Opening /dev/cu.usbserial-A50285BI @ 10400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- 4 bytes:
|
||||
hex : 41 54 5a 0d
|
||||
ascii : 'ATZ\r'
|
||||
|
||||
Exact echo of what was sent -- for a raw K-Line (KKL/FTDI) adapter this IS the expected good result: it means the wire, transceiver, and pinout are electrically sound (K-Line is half-duplex -- your own bytes always come back). It does NOT mean the ECU answered anything; only a real KWP2000 exchange (tunie info --adapter kline) exercises that.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-214846.txt)
|
||||
9
tunie/logs/tunie-raw-20260826-214859.txt
Normal file
9
tunie/logs/tunie-raw-20260826-214859.txt
Normal file
@@ -0,0 +1,9 @@
|
||||
Opening /dev/cu.usbserial-A50285BI @ 10400 baud (settle 2.0s)...
|
||||
-> b'ATZ\r'
|
||||
<- 4 bytes:
|
||||
hex : 41 54 5a 0d
|
||||
ascii : 'ATZ\r'
|
||||
|
||||
Exact echo of what was sent -- for a raw K-Line (KKL/FTDI) adapter this IS the expected good result: it means the wire, transceiver, and pinout are electrically sound (K-Line is half-duplex -- your own bytes always come back). It does NOT mean the ECU answered anything; only a real KWP2000 exchange (tunie info --adapter kline) exercises that.
|
||||
|
||||
(full session log: logs/tunie-raw-20260826-214859.txt)
|
||||
2
tunie/logs/tunie-raw-20260826-220407.txt
Normal file
2
tunie/logs/tunie-raw-20260826-220407.txt
Normal file
@@ -0,0 +1,2 @@
|
||||
Opening /dev/cu.usbserial-A50285BI @ 10400 baud (settle 2.0s)...
|
||||
could not open /dev/cu.usbserial-A50285BI: [Errno 2] could not open port /dev/cu.usbserial-A50285BI: [Errno 2] No such file or directory: '/dev/cu.usbserial-A50285BI'
|
||||
Reference in New Issue